Line Switch

On this page

Line Switch

Switches including Bowden cable actuation

Switches can be built both as 1-pole (phase conductor disconnection) and 2-pole (phase and neutral conductor disconnection) units to ensure compliance with the relevant power supply standards. As a matter of principle, high-quality products are used which meet the current requirements and which are well within the given nominal current boundaries as defined by the standard on appliance couplers.

Bowden cable for type KD/KG, CD/CGD/CG

The remote actuator cable assembly consists of a wire cable inside of a plastic insulated spiral wire casing. Identifying the proper routing of the cable assembly is important. Deviations from the line-to-line placement will require bends in the cable resulting in losses in the overall assembly. These inefficiencies show up as friction losses and lost motion. Frictional losses are increases in actuation force due to losses in the assembly. Lost motion is an undesirable difference between the input end of the assembly and the output end. The principal element of lost motion is backlash and deflection. Backlash is caused by the wire cable moving inside the casing with the change in direction of motion. It is the function of clearance between the wire cable and casing, plus the number of degrees of bend in the cable assembly. Deflection of the cable assembly, while usually low, can be minimized by anchoring the casing. This is especially true in those applications of cable assemblies with long lengths and/or large degrees of bend in the system All of these losses and resulting inefficiencies can be reduced by the equipment designer by minimizing the total degree of bend in the assembly. Because of the number of variables affecting the proper operation of any remotely actuated switch assembly, it is important that the ordering instructions be used to determine the proper cable length and to provide samples for customer approval.

Consult the figure for the minimum information required to describe the cable assembly application.

 

Order details and description

How to specify the length of the Bowden cable

Mounting parallel to the direction of actuation

B1 Actuating part

B2 Power entry module

Dimensions in mm (center of mounting hole [B1], outer surface to the center of mounting hole [B2], outer surface)

R a/ b c/

Mounting 90° to the direction of actuation

B1 Actuating part

B2 Power entry module

Dimensions in mm (center of mounting hole [B1], outer surface to the center of mounting hole [B2], outer surface)

S a/ b/ c/

Ordering example

1. Order No. socket KD14.4199.151

2. Order No. fuse drawer 4303.2024.03

3. Bowden cable (type of mounting/dimensions in mm) * R a/200 b/180 c/40

*The order No. for a customer-specific Bowden cable, you’ll get the acknowledgment.

Delivery time for a customer-specific Bowden cable sample approx. 2 weeks.

Standard Bowden cable sample, Order No. 0886.0101, ex stock

Line switch used by type

Technical data

CMF1, CMF2, CMF3, CMF4

Electrical rating acc. to IEC/EN 61058-1

10 (4) A / 250 VAC, 10 000 switch operations
6 (4) A / 250 VAC, 50 000 switch operations

Statement in ( ) at inductive load with p. f. 0.6

Electrical rating acc. to UL 1054

6 A, 125–250 VAC, 6000 switch operations
(1/4) HP, 125 VAC
(1/2) HP, 250 VAC

Statement in ( ) at inductive load with p. f. 0,45

Inrush current acc. to IEC/EN 61058-1

capacitive 70 A, 3–4 ms
continuous current 5 A
10 000 switch operations

Contact gap

≥3 mm

KM, KMF, PMM, GRM1, GRM2, GRM4

Electrical rating acc. to IEC/EN 61058-1

10 (4) A / 250 VAC, 10 000 switch operations
6 (4) A / 250 VAC, 50 000 switch operations

Statement in ( ) at inductive load with p. f. 0.6

Electrical rating acc. to UL 1054

12 A, 125–250 VAC, 6000 switch operations
(1/3) HP, 125 VAC
(1/2) HP, 250 VAC

Statement in ( ) at inductive load with p. f. 0.45

Meets switching current test acc. to UL 1054, TV-3

Inrush current acc. to IEC/EN 61058-1

capacitive 100 A, 3–4 ms
continuous current 5 A
10 000 switch operations

Contact gap

≥3 mm

KEB1, KFB1

Electrical rating acc. to DIN/VDE 0630

12 (3) A / 250 VAC, 10 000 switch operations

Statement in ( ) at inductive load with p. f. 0.6

Inrush current acc. to

capacitive 20 A, < 5 ms
continuous current 5 A

IEC/EN 61058-1

10 000 switch operations

Contact gap

≥3 mm

DC11, DC12, DC21, DC22, DD11, DD12, DD14, DD21, DD22

Electrical rating acc. to IEC/EN 61058-1

16 (4) A / 250 VAC, 10 000 switch operations
10 (4) A / 250 VAC, 50 000 switch operations
Statement in ( ) at inductive load with p. f. 0.6

Electrical rating acc. to UL 1054

16 A / 125–250 VAC, 6000 switch operations
(1) HP 125 VAC / (2) HP 250 VAC
Statement in ( ) at inductive load with p. f. 0.45

Inrush current acc. to IEC/EN 61058-1

capacitive 100 A, 3-4 ms
continuos current 5 A

KP (Switch), KEB2, KFB2, KD, CD, KG, CG, Felcom 54, Felcom 64, FKH, FKI, FKHD, FKID, 4762, 476

Electrical rating acc. to IEC/EN 61058-1

12 (4) A / 250 VAC, 10 000 switch operations
8 (8) A / 250 VAC, 50 000 switch operations

Statement in ( ) at inductive load with p. f. 0.6

Electrical rating acc. to UL 1054

15 A, 125–250 VAC, 6000 switch operations
(3⁄4) HP, 125 VAC
(11⁄2) HP, 250 VAC

Statement in ( ) at inductive load with p. f. 0.45

Meets switching current test acc. to UL 1054, TV-3

Inrush current acc. to IEC/EN 61058-1

capacitive 70 A, 3–4 ms
continuous current 5 A
10 000 switch operations

Contact gap

≥3 mm

KD Bowden cable, CD Bowden cable, KG Bowden cable, CG Bowden cable

Electrical rating acc. to IEC/EN 61058-1

6 (4) A / 250 VAC, 10 000 switch operations

Statement in ( ) at inductive load with p. f. 0.6

Electrical rating acc. to UL 1054

6 A, 250 VAC, 10 000 switch operations
8 A, 125 VAC, 10 000 switch operations

Inrush current acc. to IEC/EN 61058-1

capacitive 36 A, < 5 ms
continuous current 6 A
6000 switch operations

Contact gap

≥3 mm

EC11, EC12

Electrical rating acc. to IEC/EN 61058-1

16 (4) A / 250 VAC, 10 000 switch operations
10 (4) A / 250 VAC, 50 000 switch operations

Statement in ( ) at inductive load with p. f. 0.6

Electrical rating acc. to UL 1054

20 A, 125–250 VAC, 6000 switch operations
(1) HP, 125 VAC
(2) HP, 250 VAC

Statement in ( ) at inductive load with p. f. 0.45

Meets switching current test acc. to UL 1054, TV-3

Inrush current acc. to IEC/EN 61058-1

capacitive 100 A, 3–4 ms
continuous current 5 A
10 000 switch operations

Contact gap

≥3 mm

5145, 6145, DF11, DF12, EF11, EF12

Conditional short circuit current Inc

1'000 A

Endurance

50'000 switching cycles at In

Further technical information see data sheet TA45

6135

Conditional short circuit current Inc

2'000 A

Endurance

50'000 switching cycles at In

Further technical information see data sheet TA35 2Pole

6136

Conditional short circuit current Inc

2'000 A

Endurance

50'000 switching cycles at In

Further technical information see data sheet TA35 1Pole

Circuit breakers for equipment

In addition to switching, a Circuit Breaker for Equipment (CBE) ensures protection against overload. You will find detailed information on CBE as well as a product overview of Power Entry Modules with CBE in the product overview under Circuit Breakers for Equipment.

ScrollToTop
CloseYou will be transferred to the selected country page address. Therefore you will leave the SCHURTER main page.
If you would you like to visit your selected country page, please click on the button below:
If you would like to stay on the SCHURTER global website, please click on the button below:www.schurter.com
Note: Your country preferences for the SCHURTER Global Website are now saved.