GRF2  IEC Appliance Inlet C14 with Shielding, "Lock and Shield" Mounting

Series: GRF2

IEC Appliance Inlet C14 with Shielding, "Lock and Shield" Mounting

Free Sample Request

6 Variants


Connectors (Inlets/Outlets)

C14
Connector Logo
70° C

Description

  • Panel mount: Snap-in version rear-side
  • 2 Functions: Appliance Inlet Protection class I, with EMC-shield

Characteristics

  • Time saving “Lock and Shield” snap-in design for rear-panel mounting
  • All single elements are already wired
  • Innovative EMC-shielding with flexible steel segments for an excellent contact to the panel
  • For applications according IEC/UL 62368-1 we recommend variants with bleed resistor

Other versions on request

  • With solder terminals

Ratings IEC

10 A @ Ta 40 °C / 250 VAC; 50 Hz

Ratings UL/CSA

15 A @ Ta 40 °C / 250 VAC; 60 Hz

Dielectric Strength

> 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (2 sec)

Allowable Operation Temperature

-25 °C to 85 °C

Climatic Category

25/085/21 acc. to IEC 60068-1

IP-Protection

front side IP40 acc. to IEC 60529

Protection Class

Suitable for appliances with protection class I acc. to IEC 61140

Terminal

Quick connect terminals 4.8 x 0.8 mm Plug Connector
Solder terminal on request

Panel Thickness S

Snap-in: 1.2/1.5/2 mm

Material

Thermoplastic, black, UL 94V-0

Appliance inlet/-outlet

C14 acc. to IEC 60320-1,
UL 60320-1, CSA C22.2 no. 60320-1 (for cold conditions) pin-temperature 70 °C, 10 A, Protection Class I

MTBF

> 3'300'000 h acc. to MIL-HB-217 F

Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in  Details about Approvals
SCHURTER products are designed for use in industrial environments. They have approvals from independent testing bodies according to national and international standards. Products with specific characteristics and requirements such as required in the automotive sector according to IATF 16949, medical technology according to ISO 13485 or in the aerospace industry can be offered exclusively with customer-specific, individual agreements by SCHURTER.


Approvals

The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products.


Approval Reference Type: GRF2

Approval Logo Certificates Certification Body Description
Approval marks VDE VDE VDE Certificate Number: 40025743
Approval marks cURus UL UR File Number: E96454
Approval marks ccc CCC CCC Certificate Number: 2019180204010440


Product standards

Product standards that are referenced

Organization Design Standard Description
Approval marks IEC Designed according to IEC 60320-1 Appliance couplers for household and similar general purposes
Approval marks IEC Designed according to IEC 60939 Passive filters for suppressing electromagnetic interference
Approval marks IEC Designed according to IEC 61058-1 Switches for appliances. Part 1. General requirements
Approval marks UL Designed according to UL 60320-1 Standard for Attachment Plugs and Receptacles
Approval marks UL Designed according to UL 1283 Passive filters for suppressing electromagnetic interference
Approval marks CSA_Group Designed according to CSA C22.2 no. 60320-1 General Use Receptacles, Attachment Plugs, and Similar Wiring Devices
Approval marks CSA_Group Designed according to CSA C22.2 no. 8 Electromagnetic interference (EMI) filters


Application standards

Application standards where the product can be used

Organization Design Standard Description
Approval marks IEC Suitable for applications acc. IEC/UL 62368-1 Audio/video, information and communication technology equipment - Part 1: Safety requirements


Compliances

The product complies with following Guide Lines

Identification Details Initiator Description
Approval marks CE Selbsteklaration SCHURTER AG The CE marking declares that the product complies with the applicable requirements laid down in the harmonisation of Community legislation on its affixing in accordance with EU Regulation 765/2008.
Approval marks Zulassung_Symbol_UKCA SCHURTER AG The UKCA marking declares that the product complies with the applicable requirements laid down in the British Amendment of Regulation (EC) 765/2008.
Environment_Safety RoHS_Logo_color_CMYK_tif SCHURTER AG Directive RoHS 2011/65/EU, Amendment (EU) 2015/863
Environment_Safety China_RoHS_e_konform_eps SCHURTER AG The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March 2007. It is similar to the EU directive RoHS.
Environment_Safety REACH SCHURTER AG On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration, Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as "REACH") entered into force.

020060160000001161
LOADING...

Dimension [mm]

GRF2

1) Terminal for earth screw M4
1) Terminal for earth screw M4
This area must be conductive for optimal shielding. Do not apply paint or coatings.

Assembly Instructions

Step 1

Place the socket in top edge of the panel cut-out.
Step 2

Push the socket upwards.
Step 3

Push the socket forward into the panel cut-out.
Step 4

Release the socket. The component is self adjusting.

Short Table of Variants GRF2 Open complete table GRF2

Rated Current IEC [A] Rated Current UL [A] Filter-Type Order Number

Variant Details


A=Most Popular Free Sample Distributor Stock Check ...
  [A]                    
 
10 15 - GRF2.0212.11 ...
10 15 - GRF2.0215.11 ...
10 15 - GRF2.0220.11 ...
10 15 - GRF2.0312.11 ...
10 15 - GRF2.0315.11 ...
10 15 - GRF2.0320.11 ...

Packaging unit 100 Pcs 

020060160000001161
LOADING...
Mating Outlets/Connectors (8)

[Swipe to the left and right for more options]

4787

4787, Mounting: Screw-on mounting, Appliance Outlet: IEC Solder terminals, 10 A, Suitable for appliances with protection class I

4788

4788, Mounting: Snap-in version, Appliance Outlet: IEC Solder / Quick Connect, 10 A, Suitable for appliances with protection class I

5091

IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder, PCB or Quick-connect Terminal

4782

4782 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13

4785

4785 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13

4300-06

4300-06 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13

4781

4781 Mounting: Power Cord, Cable, Connector: IEC C15

4784

4784 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C15


16.05.2024
   
en prod By changing the catalog version (Desktop <> Mobile), the system is resetting the chosen filters