FPBB RAIL  Housing RI
Housing RI
FPBB RAIL  Housing RI with Circuit Breaker
Housing RI with Circuit Breaker
FPBB RAIL  Housing TI
Housing TI
FPBB RAIL  Housing RI with Fuseholder
Housing RI with Fuseholder
FPBB RAIL  Housing RI
Housing RI
FPBB RAIL  Housing RI
FPBB RAIL  Housing RI with Circuit Breaker
FPBB RAIL  Housing TI
FPBB RAIL  Housing RI with Fuseholder
FPBB RAIL  Housing RI

Series: FPBB RAIL

AC/DC Filter 2-Stage, DIN Rail Mounting, Overcurrent and Overvoltage Protection

Free Sample Request

50 Variants


Description

  • Single-phase line filter in standard and medical versions
  • 2-Stages filter
  • Very high attenuation
  • broadband
  • Fuseholder
  • Thermal circuit breaker
  • Surge protection

Unique Selling Proposition

  • Slim filter for DIN-rail mounting or chassis mounting
  • With fuse holder or circuit breaker for equipment
  • With overvoltage protection
  • Quick wiring with cage clamp terminals

Characteristics

  • Protection against interference voltage from the mains
    Possible interferences generated in the equipment are strongly attenuated
  • Especially designed for electric switch and control cabinets
  • Suitable for use in equipment according to IEC/UL 62368-1
  • Suitable for use in medical equipment according to IEC/UL 60601-1 (1 MOOP)
  • Suitable for medical equipment intended for permanently connection to the mains

Ratings IEC

1 - 16 A @ Ta 40 °C / 250 VAC; 50 Hz

48/250 VDC 

Ratings UL/CSA

1 - 16 A @ Ta 40 °C / 125/250 VAC; 60 Hz

48/250 VDC 

Leakage Current

standard < 1 mA (250 V / 50 Hz)

Dielectric Strength

1.7 kVDC between L-N
2.7 kVDC between L/N-PE
Test voltage (2 sec)

Allowable Operation Temperature

-40 °C to 100 °C

Climatic Category

40/100/21 acc. to IEC 60068-1

IP-Protection

IP20 IEC 60529

Protection Class

Suitable for appliances with protection class I acc. to IEC 61140

Terminal

Spring cage terminals ,
0.2 - 2.5 mm², 24 - 12 AWG

Material

Plastics, black, UL 94V-0

Circuit Breakers

Acc. IEC/EN 60934, UL 1077, CSA 22.2 no. 235
3 - 15 A
Short circuit capacity Icn:
2000 A

Climatic Category 05 / 060 / 21 acc. to IEC 60068-1

Fuseholder

1-pole, Shocksafe category PC2 acc. to IEC 60127-6
for fuse-links 5 x 20 mm

Rated Power Acceptance @ Ta 23 °C

5 x 20: 2.5 W

Power Acceptance @ Ta > 23°C

Admissible power acceptance at higher ambient temperature see derating curves

Climatic Category 40 / 085 / 21 acc. to IEC 60068-1

Surge protection

320 VAC , 420 VDC , 0.4 W

Line Filter

Standard and Industrial Version, IEC 60939, UL 60939-3, CSA C22.2 no. 8
Technical Details

MTBF

> 200'000 h acc. to MIL-HB-217 F

Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in  Details about Approvals
SCHURTER products are designed for use in industrial environments. They have approvals from independent testing bodies according to national and international standards. Products with specific characteristics and requirements such as required in the automotive sector according to IATF 16949, medical technology according to ISO 13485 or in the aerospace industry can be offered exclusively with customer-specific, individual agreements by SCHURTER.


Approvals

The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products.


Approval Reference Type: FPBB Rail

Approval Logo Certificates Certification Body Description
Approval marks ENEC_10 VDE Certificate Number: 40047767
Approval marks cURus UL UR File Number: E495089


Product standards

Product standards that are referenced

Organization Design Standard Description
Approval marks IEC_Certification_Body Designed according to IEC 60320-1 Appliance couplers for household and similar general purposes
Approval marks IEC_Certification_Body Designed according to IEC 60939 Passive filters for suppressing electromagnetic interference
Approval marks IEC_Certification_Body Designed according to IEC 60127-6 Miniature fuses. Part 6. Fuse-holders for miniature fuse-links
Approval marks UL Designed according to UL 498 Standard for Attachment Plugs and Receptacles
Approval marks UL Designed according to UL 60939-3 Passive filters for suppressing electromagnetic interference
Approval marks CSA_Certification_Body Designed according to CSA C22.2 no. 42 General Use Receptacles, Attachment Plugs, and Similar Wiring Devices
Approval marks CSA_Certification_Body Designed according to CSA C22.2 no. 8 Electromagnetic interference (EMI) filters


Application standards

Application standards where the product can be used

Organization Design Standard Description
Approval marks IEC_Certification_Body Suitable for applications acc. IEC/UL 62368-1 Audio/video, information and communication technology equipment - Part 1: Safety requirements
Approval marks IEC_Certification_Body Suitable for applications acc. IEC 60601-1 Medical electrical equipment - Part 1: General requirements for basic safety and essential performance


Compliances

The product complies with following Guide Lines

Identification Details Initiator Description
Approval marks CE SCHURTER AG The CE marking declares that the product complies with the applicable requirements laid down in the harmonisation of Community legislation on its affixing in accordance with EU Regulation 765/2008.
Approval marks Zulassung_Symbol_UKCA SCHURTER AG The UKCA marking declares that the product complies with the applicable requirements laid down in the British Amendment of Regulation (EC) 765/2008.
Environment_Safety RoHS_Logo_color_CMYK_tif SCHURTER AG Directive RoHS 2011/65/EU, Amendment (EU) 2015/863
Environment_Safety China_RoHS_e_konform_eps SCHURTER AG The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March 2007. It is similar to the EU directive RoHS.
Environment_Safety REACH SCHURTER AG On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration, Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as "REACH") entered into force.
Environment_Safety Medical SCHURTER AG Suitable for use in medical equipment according to IEC/UL 60601-1 (1 MOOP, 1 MOPP)

800840020000006523
LOADING...

Dimension [mm]

Housing RI

Housing TI


Diagrams

Diagram S1

1) Line, 2) Load
VDR only for versions with overvoltage protection
Diagram S2

1) Line, 2) Load
VDR only for versions with overvoltage protection
Diagram S3

1) Line, 2) Load
VDR only for versions with overvoltage protection
Diagram S4

1) Line, 2) Load
VDR only for versions with overvoltage protection
Diagram S5

1) Line, 2) Load
VDR only for versions with overvoltage protection
Diagram S6

1) Line, 2) Load
VDR only for versions with overvoltage protection

Attenuation Loss

1 A

3 A

6 A

10 A

12 A

16 A

1 A

3 A

6 A

10 A

12 A

16 A

1 A

3 A

6 A

10 A

12 A

16 A


Short Table of Variants FPBB RAIL Open complete table FPBB RAIL

Rated current Rated voltage Rated voltage Order Number
Free Sample

Free Sample


Please ask for free sample in order to check if the products meets your requirement for your application.
Send your delivery adress and your specific requirements.

Distributor Stock Check

Distributor Stock Check


The following links refers to the inquiry form for distributors stock information of the selected products. It allows checking for the available amount and optionally to place an order at your selected partner.
The stock availability at the distributors may also be called up separately and the desired product manually entered.
Stock Check Distributor

...
[A]   [VAC]   [VDC]          
 
1 250 250 3-103-679 ...
1 250 250 3-103-673 ...
1 250 250 3-103-699 ...
1 250 250 3-103-705 ...
1 250 250 3-103-714 ...
1 250 250 3-103-736 ...
1 250 250 3-103-980 ...
1 250 250 3-103-986 ...
3 250 250 3-103-674 ...
3 240 48 3-103-693 ...
3 250 250 3-103-700 ...
3 250 250 3-103-706 ...
3 240 48 3-103-709 ...
3 250 250 3-103-715 ...
3 240 48 3-103-720 ...
3 250 250 3-103-737 ...
3 250 250 3-103-981 ...
3 250 250 3-103-987 ...
6 250 250 3-103-675 ...
6 250 250 3-103-681 ...
6 250 250 3-103-701 ...
6 250 250 3-103-707 ...
6 240 48 3-103-710 ...
6 250 250 3-103-716 ...
6 240 48 3-103-721 ...
6 250 250 3-103-738 ...
6 250 250 3-103-982 ...
6 250 250 3-103-988 ...
10 250 250 3-103-676 ...
10 240 48 3-103-695 ...
10 250 250 3-103-702 ...
10 250 250 3-103-708 ...
10 240 48 3-103-711 ...
10 250 250 3-103-717 ...
10 250 250 3-103-739 ...
10 240 48 3-103-752 ...
10 250 250 3-103-983 ...
10 250 250 3-103-989 ...
12 250 250 3-103-677 ...
12 250 250 3-103-703 ...
12 240 48 3-103-712 ...
12 250 250 3-103-718 ...
12 240 48 3-103-753 ...
12 250 250 3-103-984 ...
15 240 32 3-103-713 ...
15 240 32 3-103-754 ...
16 250 250 3-103-678 ...
16 250 250 3-103-704 ...
16 250 250 3-103-719 ...
16 250 250 3-103-985 ...

Packaging unit 20 Pcs 

800840020000006523
LOADING...

30.09.2024
   
en prod By changing the catalog version (Desktop <> Mobile), the system is resetting the chosen filters