Series: FMBB EP

AC Filter 2-Stage, excellent Attenuation

New_Logo Free Sample Request

36 Variants


Description

  • Line filter in standard and medical version
  • 2 stage
  • Compact design
  • Very light due to partial potting

Unique Selling Proposition

  • Excellent differential and common-mode attenuation
  • Broad band attenuation
  • Completely closed steel housing
  • Wide temperature range

Characteristics

  • Designed for current applications of 1 - 36 A
  • Protection against interference voltage from the mains
    Possible interferences generated in the equipment are strongly attenuated
  • Especially designed for industrial applications such as: Frequency Converters, Stepper Motor Drives, UPS-Systems, Inverters
  • Suitable for use in equipment according to IEC/UL 62368-1
    Suitable for use in medical equipment according to IEC/UL 60601-1 (1 MOOP, 1 MOPP)

Ratings IEC

1 - 36 A @ Ta 40 °C / 250 VAC; 50 Hz

Ratings UL/CSA

1 - 36 A @ Ta 40 °C / 125/250 VAC; 60 Hz

Leakage Current

standard < 6.9 mA (250 V / 50 Hz)
low leakage current < 0.15 mA (250 V / 50 Hz)
medical (M5) < 5 µA (250 V / 50 Hz)
medical (M80) < 80 µA (250 V / 50 Hz)

Dielectric Strength

1.7 kVDC between L-N
2.7 kVDC between L/N-PE
Test voltage (2 sec)

Allowable Operation Temperature

-40 °C to 100 °C

Climatic Category

40/100/21 acc. to IEC 60068-1

IP-Protection

rear-side IP20 IEC 60529

Protection Class

Suitable for appliances with protection class I acc. to IEC 61140

Terminal

Quick connect terminal 6.3 x 0.8 mm
Bolt and nut M4

Material

Nickel plated steel

Line Filter

Standard and Medical Version, IEC 60939, UL 60939-3, CSA C22.2 no. 8
Technical Details

MTBF

> 200'000 h acc. to MIL-HB-217 F

Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in  Details about Approvals
SCHURTER products are designed for use in industrial environments. They have approvals from independent testing bodies according to national and international standards. Products with specific characteristics and requirements such as required in the automotive sector according to IATF 16949, medical technology according to ISO 13485 or in the aerospace industry can be offered exclusively with customer-specific, individual agreements by SCHURTER.


Approvals

The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products.


Approval Reference Type: FMBB EP

Approval Logo Certificates Certification Body Description
Approval marks ENEC_10 VDE Certificate Number: 40051449
Approval marks cURus UL UR File Number: E495089


Product standards

Product standards that are referenced

Organization Design Standard Description
Approval marks IEC_Certification_Body Designed according to IEC 60939 Passive filters for suppressing electromagnetic interference
Approval marks IEC_Certification_Body Designed according to IEC 60127-6 Miniature fuses. Part 6. Fuse-holders for miniature fuse-links
Approval marks UL Designed according to UL 60939-3 Passive filters for suppressing electromagnetic interference
Approval marks CSA_Certification_Body Designed according to CSA C22.2 no. 42 General Use Receptacles, Attachment Plugs, and Similar Wiring Devices
Approval marks CSA_Certification_Body Designed according to CSA C22.2 no. 8 Electromagnetic interference (EMI) filters


Application standards

Application standards where the product can be used

Organization Design Standard Description
Approval marks IEC_Certification_Body Suitable for applications acc. IEC/UL 62368-1 Audio/video, information and communication technology equipment - Part 1: Safety requirements
Approval marks IEC_Certification_Body Suitable for applications acc. IEC 60601-1 Medical electrical equipment - Part 1: General requirements for basic safety and essential performance


Compliances

The product complies with following Guide Lines

Identification Details Initiator Description
Approval marks CE SCHURTER AG The CE marking declares that the product complies with the applicable requirements laid down in the harmonisation of Community legislation on its affixing in accordance with EU Regulation 765/2008.
Approval marks Zulassung_Symbol_UKCA SCHURTER AG The UKCA marking declares that the product complies with the applicable requirements laid down in the British Amendment of Regulation (EC) 765/2008.
Environment_Safety RoHS_Logo_color_CMYK_tif SCHURTER AG Directive RoHS 2011/65/EU, Amendment (EU) 2015/863
Environment_Safety China_RoHS_e_konform_eps SCHURTER AG The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March 2007. It is similar to the EU directive RoHS.
Environment_Safety REACH SCHURTER AG On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration, Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as "REACH") entered into force.
Environment_Safety Medical SCHURTER AG Suitable for use in medical equipment according to IEC/UL 60601-1 (1 MOOP, 1 MOPP)

800840020000006525
LOADING...

Dimension [mm]

Case 09 with quick connect terminals

1) Line
2) Load
Case MB with bolt and nut M4

1) Line
2) Load
3) Nut torque 0.8...1 Nm, keep lock-nut fastened
4) Lock-nut do not unscrew
5) PE: M4x16, 1.2...1.5 Nm, keep lock-nut fastened
Case MC with quick connect terminals

1) Line
2) Load
Case UB with quick connect terminals

1) Line
2) Load
Case ME with quick connect terminals

1) Line
2) Load
Case MF with bolt and nut M4

1) Line
2) Load
3) Nut torque 0.8...1 Nm, keep lock-nut fastened
4) Lock-nut do not unscrew
5) PE: M4x16, 1.2...1.5 Nm, keep lock-nut fastened

Diagrams

Design C, D Standard and medical M80

1) Line, 2) Load

Design C, D Medical M5

1) Line, 2) Load

Medical M80

1) Line, 2) Load


Attenuation Loss

1A

3A

6A

10 A

12 A

16 A

20 A

30 A

36 A

1 A

3 A

6 A

10 A

12 A

16 A

20 A

30 A

36 A

1 A

3 A

6 A

10 A

12 A

16 A

20 A

30 A

36 A

1 A

3 A

6 A

10 A

12 A

16 A

20 A

30 A

36 A


Short Table of Variants FMBB EP Open complete table FMBB EP

Rated current Filter-Type Terminal Order Number
Free Sample

Free Sample


Please ask for free sample in order to check if the products meets your requirement for your application.
Send your delivery adress and your specific requirements.

Distributor Stock Check

Distributor Stock Check


The following links refers to the inquiry form for distributors stock information of the selected products. It allows checking for the available amount and optionally to place an order at your selected partner.
The stock availability at the distributors may also be called up separately and the desired product manually entered.
Stock Check Distributor

...
[A]              
 
1 Standard version Quick connect terminal 6.3 x 0.8 mm 3-123-509 ...
3 Standard version Quick connect terminal 6.3 x 0.8 mm 3-123-510 ...
6 Standard version Quick connect terminal 6.3 x 0.8 mm 3-123-511 ...
10 Standard version Quick connect terminal 6.3 x 0.8 mm 3-123-522 ...
12 Standard version Quick connect terminal 6.3 x 0.8 mm 3-123-523 ...
16 Standard version Quick connect terminal 6.3 x 0.8 mm 3-123-524 ...
20 Standard version Quick connect terminal 6.3 x 0.8 mm 3-123-525 ...
30 Standard version Bolt and nut M4 3-123-526 ...
36 Standard version Bolt and nut M4 3-123-527 ...
1 Low leakage current version Quick connect terminal 6.3 x 0.8 mm 3-123-537 ...
3 Low leakage current version Quick connect terminal 6.3 x 0.8 mm 3-123-538 ...
6 Low leakage current version Quick connect terminal 6.3 x 0.8 mm 3-123-539 ...
10 Low leakage current version Quick connect terminal 6.3 x 0.8 mm 3-123-540 ...
12 Low leakage current version Quick connect terminal 6.3 x 0.8 mm 3-123-541 ...
16 Low leakage current version Quick connect terminal 6.3 x 0.8 mm 3-123-542 ...
20 Low leakage current version Quick connect terminal 6.3 x 0.8 mm 3-123-543 ...
30 Low leakage current version Bolt and nut M4 3-123-544 ...
36 Low leakage current version Bolt and nut M4 3-123-545 ...
1 Medical Version (M5) Quick connect terminal 6.3 x 0.8 mm 3-123-528 ...
3 Medical Version (M5) Quick connect terminal 6.3 x 0.8 mm 3-123-529 ...
6 Medical Version (M5) Quick connect terminal 6.3 x 0.8 mm 3-123-530 ...
10 Medical Version (M5) Quick connect terminal 6.3 x 0.8 mm 3-123-531 ...
12 Medical Version (M5) Quick connect terminal 6.3 x 0.8 mm 3-123-532 ...
16 Medical Version (M5) Quick connect terminal 6.3 x 0.8 mm 3-123-533 ...
20 Medical Version (M5) Quick connect terminal 6.3 x 0.8 mm 3-123-534 ...
30 Medical Version (M5) Bolt and nut M4 3-123-535 ...
36 Medical Version (M5) Bolt and nut M4 3-123-536 ...
1 Medical Version (M80) Quick connect terminal 6.3 x 0.8 mm 3-142-126 ...
3 Medical Version (M80) Quick connect terminal 6.3 x 0.8 mm 3-142-127 ...
6 Medical Version (M80) Quick connect terminal 6.3 x 0.8 mm 3-142-128 ...
10 Medical Version (M80) Quick connect terminal 6.3 x 0.8 mm 3-142-129 ...
12 Medical Version (M80) Quick connect terminal 6.3 x 0.8 mm 3-142-130 ...
16 Medical Version (M80) Quick connect terminal 6.3 x 0.8 mm 3-142-131 ...
20 Medical Version (M80) Quick connect terminal 6.3 x 0.8 mm 3-142-132 ...
30 Medical Version (M80) Bolt and nut M4 3-142-133 ...
36 Medical Version (M80) Bolt and nut M4 3-142-134 ...

Leakage current according IEC 60939-1

20A, 30A and 36A medical filter M5 and M80, are only suitable for medical equipment intended for permanently connection to the mains.

800840020000006525
LOADING...
Alternative: High attenuation version (1)

[Swipe to the left and right for more options]

Accessories (1)

[Swipe to the left and right for more options]

DIN Rail Kit

Mounting accessory for compact 1- and 3-phase filters


30.09.2024
   
en prod By changing the catalog version (Desktop <> Mobile), the system is resetting the chosen filters