Free Sample
Please ask for free sample in order to check if the products meets your requirement for your application.
Send your delivery adress and your specific requirements.
Application Note Primary Protection in Equipmentwith further information on increased Pulse Strength and their test conditions according to international standards see Impulse Withstand Voltage
Rated Voltage
125 VAC, 125 VDC
Rated current
5 - 20 A
Breaking Capacity
up to 1000 A
Characteristic
Super-Time-Lag TT
Mounting
PCB,SMT
Admissible Ambient Temp.
-55 °C to 125 °C
Climatic Category
55/125/21 acc. to IEC 60068-1
Material: Housing
Ceramics
Material: Terminals
Ni/Sn-Plated Copper Alloy
Unit Weight
1.42 g
Storage Conditions
0 °C to 40 °C, max. 70% r.h.
Product Marking
, Rated current, Voltage, Characteristic, Breaking Capacity, Approvals
Soldering Methods
Reflow
Soldering Profile
Solderability
JESD22-B102E, Method 1
Resistance to Soldering Heat
JEDEC J-STD-020
Moisture Sensitivity Level
MSL 1, J-STD-020
Moisture Sensitivity Level
MIL-STD-202, Method 106
Thermal Shock
MIL-STD-202, Method 107
Operational Life
MIL-STD-202, Method 108 Condition F
Load Humidity Test
MIL-STD-202, Method 103
Vibration, High Frequency
MIL-STD-202, Method 204 Condition C
Mechanical Shock
MIL-STD-202, Method 213 Condition C
Resistance to Solvents
MIL-STD-202, Method 215
Temperature Cycling
JESD22 Method JA-104
Board Flex
AEC-Q200-005
Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in
Details about Approvals
SCHURTER products are designed for use in industrial environments. They have approvals from independent testing bodies according to national and international standards. Products with specific characteristics and requirements such as required in the automotive sector according to IATF 16949, medical technology according to ISO 13485 or in the aerospace industry can be offered exclusively with customer-specific, individual agreements by SCHURTER.
The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products.
Approval Reference Type: UMT-W
Approval Logo | Certificates | Certification Body | Description |
---|---|---|---|
UL | UR File Number: E41599 |
Product standards that are referenced
Organization | Design | Standard | Description |
---|---|---|---|
Designed according to | IEC 60127-7 | Miniature fuses - Part 7: Miniature fuse-links for special applications | |
Designed according to | UL 248-14 | Low voltage fuses - Part 14: Supplemental fuses |
Application standards where the product can be used
Organization | Design | Standard | Description |
---|---|---|---|
Suitable for applications acc. | IEC/UL 62368-1 | Audio/video, information and communication technology equipment - Part 1: Safety requirements |
The product complies with following Guide Lines
Identification | Details | Initiator | Description |
---|---|---|---|
SCHURTER AG | The CE marking declares that the product complies with the applicable requirements laid down in the harmonisation of Community legislation on its affixing in accordance with EU Regulation 765/2008. | ||
SCHURTER AG | The UKCA marking declares that the product complies with the applicable requirements laid down in the British Amendment of Regulation (EC) 765/2008. | ||
SCHURTER AG | Directive RoHS 2011/65/EU, Amendment (EU) 2015/863 | ||
SCHURTER AG | The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March 2007. It is similar to the EU directive RoHS. | ||
SCHURTER AG | SCHURTER strives to offer our customers halogen free products. | ||
SCHURTER AG | On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration, Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as "REACH") entered into force. |
Rated Current In | 1.0 x In min. | 2.5 x In min. | 4.0 x In min. | 4.0 x In max. | 10.0 x In min. | 10.0 x In max. |
---|---|---|---|---|---|---|
5 A - 20 A | 4 h | 3.5 s | 600 ms | 20 s | 25 ms | 1 s |
Rated Current [A] | Rated Voltage [VAC] | Rated Voltage [VDC] |
Order Number
|
Free Sample Free Sample
|
Distributor Stock Check Distributor Stock Check
|
... | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
5 | 125 | 125 | 3-122-712 | ... | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
5 | 125 | 125 | 3-122-713 | ... | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
7.5 | 125 | 125 | 3-122-714 | ... | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
7.5 | 125 | 125 | 3-122-715 | ... | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10 | 125 | 125 | 3-122-716 | ... | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10 | 125 | 125 | 3-122-717 | ... | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
15 | 125 | 125 | 3-122-718 | ... | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
15 | 125 | 125 | 3-122-719 | ... | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
20 | 125 | 125 | 3-122-720 | ... | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
20 | 125 | 125 | 3-122-721 | ... | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
1) UL = 350 A @ 125 VAC / 350 A @ 125 VDC 1) Internal tests = 1'500 A @ 125 VAC with cos(φ) ≥ 0.75 / 1500 A @ 250 VDC with τ <0.3 ms 2) UL = 350 A @ 125 VAC / 350 A @ 125 VDC 2) Internal tests = 1'000 A @ 125 VAC with cos(φ) ≥ 0.75 / 500 A @ 125 VDC with τ <0.3 ms ____________________________________________________________________________ All measurements are carried out on a test board according to IEC 60127 with the following tracks: 5 A: Track width 5.0 mm, Cu layer 35 µm 6.3 A, 7.5 A: Track width 7.5 mm, Cu layer 70 µm 10 A: Track width 7.5 mm, Cu layer 140 µm 15 A, 20 A: Track width 10 mm, Cu layer 140 µm |
Packaging Unit
acc. IEC 60286-3 Type 2a |
|